Pump Interface Manual v1.3 Wayne 41
03/20/03 Gasboy CFN Series
The SCII K1 (port 1) or K2 (port 3) jumper patch must be configured for a Wayne port.
Below is the system layout for the Wayne interface and a SCII.
K2 Jumper Settings.
CFN3 cabling
The Wayne 2400 Controller is connected to either ports 4, 5 or 6 of the CFN3 with a C06006
cable. The cable comes in 8 ft lengths. The maximum distance for this cable is 100 ft.
SCII and CFN3 Configurations
SYS_PAR.BIN, page 8
In SYS_PAR.BIN (page 8), the “Special pump handler channel” parameter must be configured
for the ports listed under cabling for either the SCII or CFN3 (see previous sections).
Male DB-25P
Connector
Female DB-
25S
Connector
22
33
44
55
66
77
88
20 20
Site Controller II
Wayne
2400
Site Controller
Wayne Cable
C04654
To pumps/dispensers
Interface cable must be plugged into port 3 or port 1
of the Site Controller II