032093 Rev. 7261 Page 1
TOTALIZER/PULSER/GEAR TRAIN ASSEMBLY RETROFIT KIT
FOR 9850A, 9850AX, 9850AXTW, 2650A, 2650AX, 2650AXTW UNITS (See NOTE)
This instruction sheet shows how to install the totalizer/pulser/gear train assembly kit for Series 9850A/2650A
pumps and dispensers. The available kits are listed below. Refer to the table to determine the contents for each
kit. Be sure to follow all warnings and safeguards as outlined in the enclosed Warnings and Safeguards sheet
before working on the unit.
NOTE: If your pump/dispenser is a 9850A, 9850AX, 9850AXTW, with a serial number higher than 472238 or
a 2650A, 2650AX, 2650AXTW with a serial number higher than 0009491-T, you do not need this kit.
Instead, just order the Totalizer kit for your model as listed in the 9800A Parts List, 035297 or 2600A
Parts List, T35297. The serial number appears on the UL nameplate on the side of the unit.
KIT SUMMARY
032094 Model 9850A, 2650A, Liter
032095 Model 9850A, 2650A, Gallon
032096 Model 9850AXTW, 2650AXTW, Liter
032097 Model 9850AXTW, 2650AXTW, Gallon
032098 Model 9850AX, 2650AX, Liter
032099 Model 9850AX, 2650AX, Gallon
KIT CONTENTS
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - KIT CONTENTS

032093 Rev. 7261 Page 1TOTALIZER/PULSER/GEAR TRAIN ASSEMBLY RETROFIT KITFOR 9850A, 9850AX, 9850AXTW, 2650A, 2650AX, 2650AXTW UNITS (See NOTE)This in

Strany 2 - Pulser Detail

032093 Rev. 7261 Page 21. Remove front and rear doors to gain access to the interior ofthe pump.2. Remove front and rear bezel by removing two screw

Strany 3

032093 Rev. 7261 Page 3Install Totalizer10. Remove existing hardware from totalizer window on side of unit. Setaside for later use or replace.11. I

Strany 4

032093 Rev. 7261 Page 417. On the LCD Display PCB, set the K2, K4, and K6 decimal point jumpers to hundredths as shown below. Thedisplays will sho